As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NR 1 SLAT HAS NUMEROUS UNIDENTIFIED DENTS, SLAT UPPER T/E WEDGE. INSPECTED NR 1 SLAT FOUND NUMEROUS DENTS, ALL ARE IN LIMITS OF SRM 57-43-02. TAP AND DELAMATION TEST C/W ON RC 56-0557-8-0072 . NR 1 SLAT NEEDS TO BE ADDED TO MONITOR INSP. INSTALLED I/D TAG ON NR 1 SLAT DAMAGED AREA.