What was found
FOUND DENT AT LOCATION STR 16L, BS 620. FOUND DENT TO BE 1.125" L & 0.053" D. IAW SRM 53-00- 01, FIGURE 101, DETAIL 3, CRITERIA, A/Y RATIO TO BE 21.22, LESS THAN 30 IS OUT OF LIMITS. NOTE I DENT REPAIR MAY BE DELAYED WITH EXAMINATIONS AT EVERY 300 FLIGHT CYCLES & NOT TO EXCEED 24 MONTHS. REPAIR MUST BE MADE AT OR BEFORE NEXT C-CHECK. REMOVED SHARP EDGES OF DENT, TREATED, PRIMED, AND PAINTED AREA. DENT STICKER INSTALLED & ADDED TO ADF FILES. PERFORMED 10X INSPECTION, NO CRACKS NOTED. CHANGED TERM ACTION FROM HCK TO LCK IAW SRM 53-00-01, PAGE 103.