What was found
CORROSION ON CORNER FITTING FRAME 16 AT FWD GALLEY AREA ON STR 23L, REPLACED CORNER FITTING ON FRAME 16 AT FWD GALLEY AREA LEVEL STR 23L IAW SRM 51-72-11 AND DWG D53112109. MEASURES OF CORROSION ARE: L=0.722", W=0.123", D=0.040".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON CORNER FITTING FRAME 16 AT FWD GALLEY AREA ON STR 23L, REPLACED CORNER FITTING ON FRAME 16 AT FWD GALLEY AREA LEVEL STR 23L IAW SRM 51-72-11 AND DWG D53112109. MEASURES OF CORROSION ARE: L=0.722", W=0.123", D=0.040".