What was found
LIGHTNING STRIKE ON FUSELAGE SKIN AT AFT UPPER CORNER LT WINDOW BELT BETWEEN BS 693 AND 712. LIGHTNING STRIKE WAS REPAIRED AND DIMENTIONS AS FOLLOW: (UT) WAS ACCOMPLISHED IAW NDT-SPM 04-00-07, PARA 5, FIG. 5, ON AFT UPPER CORNER ORIGINAL THICKNESS 0.090 AND REMAINING THICKNESS 0.083, THEREFORE IT IS WITHIN LIMITS IAW ER/A 541576-14, REV ORIGINAL.