What was found
MAINTENANCE DISCOVERED A LARGE DENT NEXT TO THE C2 CARGO DOOR AT BS 712, S-26L. MAINTENANCE CUT OUT THE DENT AND REPAIRED IAW ER/A 531636-14 INSTRUCTIONS. ER/A 531636-14 INSTALLS A REPAIR FILLER AND DOUBLER, COVERING THE DAMAGED AREA AND THE NEARBY FACTORY DOUBLER. THIS LOG PAGE PROVIDES TRACKING FOR THE DTE RESTRICTION ASSOCIATED WITH ER/A 531636-14 ONLY. ASSOCIATED ER/A 00-531636 ADDED FOR AC 9016. REDEFERRED LOG TO QC, ESTABLISH MONITOR INSPECTION, 20-0553-8-9369, SN 09016, L/L SEC I DTA. ER/A 531636-14, REV A IS CURRENT. DTA RESTRICTION REMOVED, LOGPAGE TO BE TERMINATED. CLOSED LOG AND REMOVED MONITOR INSP IAW ALERT 07DEC15 AND LOG COMMENTS.