What was found
PROTRUSION ON EXTERNAL FUSELAGE, SKIN BS 200-207 BETWEEN LONGERON 30-29 LT ALSO 214 LONGERON 28-29 LT. DENTS ON FUSELAGE SKIN WERE MEASURED PRESENTING THE FOLLOWING CONDITIONS: BS 200-207, LONGERON 29-30 LT X= DEPTH= 0.042 ", D= DIMENTION= 1.500". D/X = 1.560/0.038=41.05. IT IS WITHIN LIMITS IAW SRM 53-04-01, PARR 7E, CONDITION 1B.