What was found
WHILE WORKING NRC 100-41, DISCOVERED 2 EA DENTS ON AFT CARGO FRAME BS 1320 BETWEEN STR 24R AND STR 26R. CUTOUT 2 EA DAMAGED AREAS AT BS 1320 BETWEEN STR 24R & 26R IAW SRM 53-00-07, REPAIR 5. DIMENTIONS OF BOTH CUTOUTS W=1.0 " X L=1.125" X 0.5"R ORIGINAL MATERIAL THICKNESS .071". ACCOMPLISHED REPAIR IAW SRM 53-00-07, REPAIR 5. REPAIR IS CAT B, ZONE 1 WITH THRESHOLD INSPECTION TO START AT 50000 F/C & REPEAT INSPECTION EVERY 12000 F/C THEREAFTER USING HFEC & DETAILED INSPECTION. ACFT IS CURRENTLY AT 17053 F/C REF. SRM 53- 00-07, REPAIR 5, FIG 201, TABLE II, PAGE 210. INSTALLED ID TAG IAW PS 900-5-1, NR 04.