What was found
DENT ON LT SIDE FUSELAGE OUTBD OF F/C EXT SERVICE PANEL. FOUND. LOCATED AT SEC 41, BS 395-418, STRINGERS S23- S24 LT SIDE. INSPECTED AND FOUND TO BE WITHIN LIMITS OF SRM 53-00-01 FIG 101. BUT A/Y RATIO WAS LES THAN 30... REQ VIS INSP EVERY300 FLT CYCLES. PERMANENT REPAIR IS MADE AT OR BEFORE NEXT C CHECK NOT TO EXCEED 24 MONTHS. OK FOR SERVICE. ADDED STATEMENT: LOGPAGE 2167253 & NRC 100-93 CREATED TO ACCOMPLISH REQUIRED REPETITIVE INSPECTIONS FOR THE INSTALLED DOUBLER. CLOSED LOG AND REMOVED MONITOR INSPECTION IAW PERM REPAIR INSTALLED AND TRACKING INSPECTION ON LP 2167253.