What was found
LIGHTNING STRIKE AT BS 984 AND STR 4 RT. DRILLED OUT DAMAGE IAW SRM 53-00-01 REPAIR SECT 1, PARA 3. HFEC INSPECTION OF REPAIR AREA OK, REF SRM 53-00-01, REPAIR 6 QC1707. C/W TEMP REPAIR IAW SRM 53-00-01, REPAIR 6, SECTION 1 DUI REQUIRED EVERY 500 CYCLES NOT TO EXCEED 1000 CYCLES OR 24 MONTHS. REDEFERRED LOG TO QC, ESTABILISHED MONITOR INSPECTION 21-0553-8-8823, SN 05814, REP 21-0553-8-8833, SN 05814 L/L.