What was found
LIGHTNING STRIKE AT BS 960 AND STR 4RT MARKED. DRILLED OUT DAMAGE IAW SRM 53-00-01. REPAIR SECT 1, PARA 3. HFEC INSPECTION OF REPAIR AREA OK REF SRM 53-00-01, REPAIR 6. C/W TEMP REPAIR IAW SRM 53-00-01, REPAIR 6 SECTION 1, DUI REQUIRED EVERY 500 CYCLES NOT TO EXCEED 1000 CYCLES OR 24 MONTHS. REDEFERRED LOG TO QC, ESTAB MONITOR INSPECTION, 21-0553-8-8822, SN 05814 REP, 21-0553-8-8834, S/N 05814 L/L.