What was found
MAIN CABIN BETWEEN BS 149-200, LBL 8 FLOOR SUPPORT CORRODED. REMOVED CORROSION FROM MAIN CABIN FLOOR SUPPORT BS 149-200, LBL 8, WITH 100 PERCENT MATERIAL LOSS ORIGINAL MATERIAL .125". R & R WITH NEW FLOOR SUPPORT IAW SRM 51-41-05, 51-41-02, AND DWG 9936534, REV BW.