What was found
CRACK ON FWD SERVICE DOOR PAN UPPER HINGE CUT OUT. SERVICE DOOR PAN WAS REPAIR IAW SRM 52-03, FIG 3. HFEC INSPECTION WAS ACCOMPLISHED IAW NDTSPM PART 6 06-10-01.001. NO CRACKS WERE FOUND AFTER STOP DRILLING.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON FWD SERVICE DOOR PAN UPPER HINGE CUT OUT. SERVICE DOOR PAN WAS REPAIR IAW SRM 52-03, FIG 3. HFEC INSPECTION WAS ACCOMPLISHED IAW NDTSPM PART 6 06-10-01.001. NO CRACKS WERE FOUND AFTER STOP DRILLING.