What was found
CRACKED INTERCOSTAL BETWEEN BEAM 3 AND 4 AND MECHANISM AREA AT FWD MAIN ENTRANCE DOOR. THE INTERCOSTAL WAS REPLACED IAW DWG 9955763 REV M AND SRM 51-30-1, 51-30-2, 51-30-5 AND 51-10-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED INTERCOSTAL BETWEEN BEAM 3 AND 4 AND MECHANISM AREA AT FWD MAIN ENTRANCE DOOR. THE INTERCOSTAL WAS REPLACED IAW DWG 9955763 REV M AND SRM 51-30-1, 51-30-2, 51-30-5 AND 51-10-4.