What was found
TWO DENTS ON AFT CARGO FUSELAGE FRAME AT BS 1400 AT AND JUST BELOW STR 23L. NO DENTS ALLOWED ON FRAME FLANGE IAW SRM 53-00-07, FIG 101, ALLOWABLE DAMAGE 1. REPAIRED FRAME AT BS 1400 BELOW STR 23L IAW SRM 53-00-07, REPAIR 5. REPAIR IS PERMANENT CAT "B" ZONE 1 WITH THRESHOLD INSPECTION TO START AT OR BEFORE 50000 F/C & REPEAT INSPECTION EVERY 12000 F/C THEREAFTER USING HFEC & DETAILED INSPECTION. ACFT IS CURRENTLY AT 17053 F/C REF SRM 53-00-07, REPAIR 5, FIG 201, TABLE II, PAGE 210. DENT TRIMOUT NR 1 MEASURE 1.8" X 0.9" X 0.5"R , TRIMOUT NR 2 MEASURE 1.4 " X 0.9" X 0.5"R. ACCOMPLISHED ER/A 541046-14, REV ORIGINAL FOR THE FABRICATION OF FRAME STANCHION BRACKET, PN 146N1047-1. FOUND DISTURBED IN THE REPAIR INSTALLATION AT FRAME BS 1400, STR 22L.