What was found
MAIN CABIN FLOOR SUPPORT, BS 195, LBL 22-LBL 44 CORRODED. CORROSION DAMAGE ON MAIN CABIN FLOOR SUPPORT BS 195, LBL 22-LBL 44 FOUND TO BE OUT OF LIMITS, ORIGINAL THICKNESS .070", MATERIAL LOSS .029", MATERIAL REMAINING .041" DIM 3" X 1" IAW SRM 53-00-00, 53-10-51, AND DWG S2929169, REV B. REPLACED FLOOR SUPPORT IAW SRM 51-41-02 AND DWG 9936534, REV BW.