What was found
CORROSION ON RT CUSP WEB BETWEEN X=-54 TO X=-60 AND BETWEEN BS 1041-1060, UPPER AND LOWER SURFACE, AT CABIN FLOOR STRUCTURE. CUSP WEB WAS REPAIRED IAW SRM 51-30-2, SRM 51-10-3, PAR 14, 21, 26 & 38, SRM 53-01, FIG 1, SRM 53- 05, FIG 131A-13, TOPP 30-10-70.