What was found
CRACKED DOOR LANDING AT FWD OTBD CORNER OF GROUND CONDITIONED AIR SUPPLY DOOR CUTOUT. REMOVED DOOR ASSY FOR CONDITIONED AIR GROUND CONNECTION IAW SRM 51-41-01. REMOVED DOOR LANDING IAW SRM 51-41-02. REMOVED AIR GROUND CONNECTION IAW SRM 51-41-02. FABRICATED NEW DOOR LANDING FROM 7075-T6 IAW SRM 51-40-08 AND DWG 5911429, REV DZ. APPLIED FINISH AS REQUIRED IAW SRM 51-10-04. INSTALLED PAN AND NEW DOOR LANDING IAW SRM 51-41-02, INSTALLED DOOR ASSY IAW SRM 51-41-01.