What was found
TWO LIGHTNING STRIKES ON CROWN OF FUSELAGE BETWEEN BS 720 AND 760. DRILLED OUT DAMAGE IAW SRM 53-00-01, REPAIR 6, SECTION 1. PARAGRAPH 3, PERFORMED BHEC INSPECTION IAW SRM 53-00-01, REPAIR 6. NO DEFECTS NOTED. INSTALLED BLIND RIVETS, 2 EA IAW SRM 53-00-01, REPAIR 6, SECTION 1, PARA 3.