What was found
TWO LIGHTNING STRIKES ON CROWN OF FUSELAGE BETWEEN BS 720 AND 760. DRILLED OUT DAMAGE IAW SRM 53-00-01. REPAIR 6, SECTION 1, PARA 3. PERFORMED BHEC INSPECTION IAW SRM 53-00-01 REPAIR 6. NO DEFECTS NOTED. INSTALLED RIVETS IAW SRM 53-00-01, REPAIR 6, SEC 1 PARA 3.