What was found
CORROSION ON LT TIE TRACK BETWEEN BS 1060 TO 1211 AT C3. NEW TIE TRACK WAS DRILLED IAW SRM 51-10-4. DRILLED NEW TIE TRACK WAS TREATED AND PAINTED IAW SRM 51-10-3 PAR 14, 21, 38. NEW TIE TRACK WAS INSTALLED IAW SRM 51-30-1 AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON LT TIE TRACK BETWEEN BS 1060 TO 1211 AT C3. NEW TIE TRACK WAS DRILLED IAW SRM 51-10-4. DRILLED NEW TIE TRACK WAS TREATED AND PAINTED IAW SRM 51-10-3 PAR 14, 21, 38. NEW TIE TRACK WAS INSTALLED IAW SRM 51-30-1 AND 51-30-2.