What was found
LIGHTNING STRIKE AT BS 1070 2" ABOVE STR 5R. DRILLED OUT DAMAGE AREA CONTAINED ON SKIN WITHIN ALLOWABLE DAMAGE LIMITS. SRM 53-10-01, SKIN ID SRM 53-00-01, SEC II. INSTALLED BLIND RIVET. RIVET MUST BE INSPECTED AT OR BEFORE 500 CYCLES. RIVET MUST BE REPLACED BEFORE 1000 FLIGHT CYCLES OR 24 MONTHS. REAPPLIED FINISH. PERFORMED REPETATIVE INSPECTION IAW SRM 53-00-01 NO FURTHER DAMAGE NOTED. CONTINUE ON MONITOR.