What was found
LIGHTNING STRIKE AT BS 1120 5" BELOW STR 5R. DRILLED OUT DAMAGE AREA CONTAINED ON SKIN WITHIN ALLOWABLE DAMAGE LIMITS. SRM 53-10-01, SKIN ID SRM 53-00-01, SEC II. INSTALLED BLIND RIVET. RIVET MUST BE INSPECTED AT OR BEFORE 500 CYCLES. RIVET MUST BE REPLACED BEFORE 1000 FLIGHT CYCLES OR 24 MONTHS. REAPPLIED FINISH. GAINED ACCESS TO AREA. REMOVED BLIND FASTENER SRM 53-00 -01. PERFORMED OPEN HOLE EDDY CURRENT INSPECTION IAW SRM 53-00-01, REPAIR 6. NO CRACKS NOTED. OVERSIZED HOLE TREATED AREA AND INSTALLED SOLID FASTENER IAW SRM 53-00-01, REPAIR 6. RESTORED FINISH AND CLOSED ACCESS TERMINATING ACTION COMPLIED WITH, REQUEST TO CLOSE MONITOR.