What was found
ONE CRACK FOUND ON LT MED NR 5 AFT UPPER CORNER OF THE CUTOUT LENGTH 1.5". REPAIRED CRACK AT LT MED NR 5 DOOR AFT UPPER CORNER OF THE CUT OUT AREA IAW SRM 51-40-02, ERV.95 AND DWG 675U0001, SHEET 2. HFEC INSPECTION AT THE CUT OUT. NO CRACK FOUND REF TO NDT PART 6, 51-00-00 PROCEDURE 23 AND OPEN HOLE HFEC INSPECTION AT THE FASTENER HOLES. NO CRACK FOUND REF TO NDT PART 6 51-00-00. PROCEDURE 16, JOB COMPLETED. REQUIRE INSPECTION ITEM COMPLETED.