What was found
LEFT FLOORBEAM TO WEB VERTICAL ATTACH FITTING AT APPROXIMATELY LBL 45, FS 737, IS CRACKED IN 2 PLACES AT BOTTOM END. REMOVED ATTACH FITTING FOR REPLACEMENT IAW SRM 51-41-02, PAGE 40. INSTALLED NEW FITTING ON 3925812-1 IAW SRM 5141-05, PAGE 1.