As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
APPROXIMATELY ONE INCH DIA HOLE IN AFT CARGO BAY FLOOR 18 IN INBD OF DOOR SILL AND 3 IN FWD OF FWD DOOR CUTOUT. ACCOMPLISHED ERA 489384-14MA, REV F SECTION, I MUST ACCOMPLISH SECT III SPPED TAPE REPAIR INSPECTION EVERY 50 FLT HRS AND SECT II TEMPOARY REPAIR DOUBLER WITH BLIND FASTENERS WITHIN 150 FLT HRS.