What was found
CORROSION ON LT CUSP WEB BS 653 TO BS 638.5 X=54, X=60. FABRICATED DOUBLER AND RING DOUBLER REPAIR IAW SRM 53-05, FIG 131A-14, SHEET 1. OK TO TREAT AND PAINT IAW SRM 51-10-3 PAR 14 AND 21 AND OK TO INSTALL IAW SRM 51-30-2 AND OK TO APPLY CIC IAW SRM 51-10-3, PAR 38.