What was found
CORROSION ON LT CUSP WEB FROM BS 579 TO BS 598 AT CABIN FLOOR STRUCTURE. DAMAGE AREA WAS REMOVED, REPAIR PARTS WERE FABRICATED AND REPAIR PARTS WERE TREATED, PAINTED AND REPAIR PARTS WERE INSTALLED IAW SRM 53-05, FIG 131A-14 AND 51-10-3 PAR 14 AND 21 AND 38.