What was found
CRACKED STOP FITTING NR 1 AND NR 5 AT AFT AREA OF C2 DOOR. CRACKED STOPS FITTING NR 1 AND NR 5 WERE REPLACED IAW SRM 51-30-1 AND 51-30-5 AND CRACK UNDER STOP FITTING NR 1 WAS ATTENDED WITH CARD NR 393 AC ZONE 100, NRC 20000102642.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED STOP FITTING NR 1 AND NR 5 AT AFT AREA OF C2 DOOR. CRACKED STOPS FITTING NR 1 AND NR 5 WERE REPLACED IAW SRM 51-30-1 AND 51-30-5 AND CRACK UNDER STOP FITTING NR 1 WAS ATTENDED WITH CARD NR 393 AC ZONE 100, NRC 20000102642.