What was found
CRACK ON CHANNEL AT LT FLOOR PANEL NR 389A. CRACK STOPPED DRILL, DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 53-05, FIG 131, 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON CHANNEL AT LT FLOOR PANEL NR 389A. CRACK STOPPED DRILL, DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 53-05, FIG 131, 51-30-02.