What was found
CRACK INDICATION ON EXTERNAL DOUBLER AT BS 954 BETWEEN STR 14R-15R, POSSIBLE FRETTING/INTERGRANULAR CORROSION. ACCOMPLISHED BLEND OUT OF DEFECTS ON EXTERNAL DOUBLER AT BS 954 BETWEEN STR 14R-15R IAW ERA 472309-14, REV C, PERFORMED LFEC INSP OF AREA IAW NDTM PT 6, 53-00-06 NO DEFECTS NOTED. CONTINUE WITH SUPPLEMENTAL INSPECTION PRIOR TO 37,500 TOTAL ACFT CYCLES AND REPETITIVELY EVERY 12,000 CYCLES REF LOG 2294323 FOR INSPECTION.