What was found
ERA369014-14, REV C, FS 574, STR 27L/LIGHTNING STRIKE DAMAGE TIME LIMITED. ERA REP CYC ACTL/2100 CONVERTED TO SCEPTRE ON 09OCT13 03:51 UTC, REDEFERRED LOG TO QC, ESTAB MONITOR INSPECTION; 10-0553-8-0406, SN 674, REP SEC II. OPENED FWD CARGO FLOOR PANEL FOR INSPECTION ACCESS. C/W INSPECTION IAW MON 56 REP, 1129533, INSP, EC, ERA 369014C-11, FUS, 674. CLOSED FWD CARGO FLOOR PANEL. C/W HFEC INSPECTION IAW ERA 369014-14, REV C SECTION 2 REP INSPECTION. NO CRACKS. COMPLETED INSTALLATION OF FLOOR PANEL THAT WAS PARTIALLY REMOVED IN PRIOR STEP.