What was found
DOUBLER REPAIR INSTALLED ON THE AFT CARGO DOOR AS ACCOMPLISHED ON JC NR 60, LOG 6528906, REF SRM 52-30-01, REPAIR 4, REF J/C NR 60 & LOGPAGE 6528906, PERMANENT MAJOR REPAIR INSTALLED ON LWR SKIN SECTION OF THE AFT CARGO DOOR REQUIRE A THRESHOLD INSPECTION AT 37500 DOOR FLIGHT CYCLE WITH REPEAT INSPECTION EVERY 3000 F/C, ALTERNATIVE METHOD I, USING LFEC TO INSPECT THE SKIN EXTERNALLY THROUGH THE DOUBLER REF SRM 52-30-01, FIG 201, REPAIR 4, TABLE IV, PAGE 204.