What was found
ELONGATED HOLE ON RT CUSP WEB BS 1250 AND X=-49 UPPER SURFACE. FASTENERS WERE REMOVED, DAMAGE WAS REMOVED, REPAIR PART WAS FABRICATED, NEW REPAIR PART WAS TREATED, PAINTED AND INSTALLED. CIC WILL BE APPLIED WITH NRC 20000100381 CARD NR 20 ZONE 201 IAW SRM 53-05, FIG 131A-17, 51-10-3, PAR 14 , 21, 51-30-2.