What was found
CRACK ON CHANNEL AT FLOOR PANEL 541A IN PASSENGER CABIN. FLOOR PANEL REPAIRED IAW SRM 53-05, FIG 131B, HFEC INSPECTION WAS PERFORMED AND NO CRACKS INDICATION WERE FOUND AFT STOP DRILL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON CHANNEL AT FLOOR PANEL 541A IN PASSENGER CABIN. FLOOR PANEL REPAIRED IAW SRM 53-05, FIG 131B, HFEC INSPECTION WAS PERFORMED AND NO CRACKS INDICATION WERE FOUND AFT STOP DRILL.