What was found
RT WING, NR 6 SLAT CENTER SECTION OF T/E WEDGE HAS A DENT 2 X 2 INCHES. EVALUATED RT WING NR 6 SLAT CENTER SECTION OF T/E WEDGE IAW SRM 57-43-02, FIG 101, PGS 101-105 AND FOUND DENT TO BE OUT OF LIMITS. TAP TESTED TYPE A L/E T/E WEDGE AND FOUND NO DEFECTS IAW SB 757-57-0066. APPLIED PERMANENT REPAIR TO OUT OF LIMITS DENT IAW SRM 57-43-02, REPAIR NR 1, FIG 201, SRM 51- 70-10 REPAIR 3 AND 4. INSTALLED REPAIR ID DECAL IAW PS900-5-1 NR 04, DECAL CONDITION MONITOR AT L-CHECK INTERVALS IAW TOPP 30-10-70.