What was found
LIGHTNING STRIKE DAMAGE AT BS 500, ETR 7, LT SIDE 2 LOC. REMOVED DAMAGE AT LOWER LOCATION W 5/32 DRILL BIT HFEC INSPECTED IAW SRM 53-00-01, REPAIR 6 WITH NO ITEMS AT LOCATION BS 500, STR 7L. CUTOUT DAMAGE IAW SRM 53-00-01, REPAIR 2, FIG 201. C/W HFEC OF CUTOUT EDGE AND BHEC OF FASTENER HOLES COMMON TO REPAIR IAW SRM 53-00-01, REPAIR 2 FIG 201 WITH NO ITEMS NOTED FABRICATED REPAIR PARTS IAW SRM 53-00-01, REPAIR 2, FIG 201 OK TO INSTALL REPAIR PARTS PER B757 SRM 53-00-01 REPAIR 2 FIG 201. INSTALLED REPAIR PARTS PER SRM 53-00-01, REPAIR 2, FIG 201. OK FOR PRIMER, PAINT, AND ID TAG. INSPECTED REPAIR INSTALLATION IAW SRM 53-00-01, REPAIR 2, FIG 201.