What was found
CRACK ON INTERCOSTAL OF INTERNAL STRUCTURE BETWEEN BEAMS NR 4 TO NR 5 AND BS 186 AT FWD ENTRY DOOR. INSTERCOSTAL OF INTERNAL STRUCTURE BETWEEN BEAM NR 4 TORN 5 WAS REMOVED DUE TO CRACK, AND NEW INSTERCOSTAL WAS INSTALLED IAW SRM 51-30-2 AND 51-30-5.