What was found
FLIGHT COMPARTMENT FLOOR PANEL 211AJF IS DAMAGED. CUTOUT DAMAGED AREA ON FLOOR PANEL NR 211AJF DIM. 2.1250" X 3" IAW SRM 53-10-50 REPAIR 1. FABRICATED REPAIR DOUBLER DIM. 4.3750" X 3.5" X .032", AND FILLER DIM. 2.1250" X 3" X .025", AND INSTALLED REPAIR PARTS IAW SRM 53-10-50, REPAIR 1.