What was found
CORROSION AT FUEL ACCESS PANEL 1460C ON COUNTERSINK. CORROSION ON COUNTERSINK WAS REMOVED 3 HOLES ON ADJACENT OUT OF LIMITS, HOLES AND COUNTERSINK OUT OF LIMITS WERE REWORKED AND REPAIRED IAW SRM 51-22-2A, CONDITION II, AREA REWORKED WERE TREATED IAW SRM 51-10-3, PAR 21 AND FUEL ACCESS PANEL WAS PAINTED IAW PS 900-3-6, NR 36.