What was found
MAIN CABIN FLOORBOARD 222YF IS DELAMINATED WITH 2 EA DAMAGED STIFFENERS AND 1 EACH COVER DAMAGED. MAIN CABIN FLOORBOARD FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOORBOARD IAW SRM 51-41-08, 51-40-08, 53-20-50, REPAIR 3, AND DWG 9936639, REV P.