What was found
MAIN CABIN AFT SECTION FLOOR SUPPORT AT R-4 DOOR HAS CORROSION AT FASTENER LOCATIONS BS 1655-1675, RBL 54. REMOVED CORROSION FROM R-4 DOOR CUTOUT FLOOR SUPPORT BS 1655-1675, RBL 54. FOUND SUPPORT TO BE OUT OF LIMITS WITH 100 PERCENT MATERIAL LOSS IAW SRM 51-10-02, 53-60-15. R & R FLOOR SUPPORT, PN 146N524606, PO 663DN-00086 IAW SRM 51-40-02, 51-40-05, AND DWG 146N5230, REV D.