What was found
LIGHTNING STRIKES, FOUR ON WINDOW FRAME BETWEEN BS 674 TO 693 AND LONGERONS 14TO 15R. MEASURE REWORKED AREAS, UT) WAS ACCOMPLISHED IAW DC/MD NDT SPM 04-00-07 PAR 5, FIG 3, SHEET 1 AND 2. BLEND OUT ON ZONE CRITICAL BLEND OUT, 2 THE ORIGINAL THICKNESS ES .120 AND REMAINING THICKNESS .115. THEREFORE AREA IS WITHIN LIMITS IAW ER/A 545077-14, REV ORIG. HFEC WAS ACCOMPLISHED AND CRACKS WERE NOT FOUND I.A.W ER/A 545077-14. REV ORG. PERFORM HFEC INSPECTION WITHIN EVERY 24 MONTHS AFTER SECTION I UNTIL ACCOMPLISHED OF SECTION III. PERFORM PERMANENT REPAIR ON OR BEFORE 84,500 TOTAL FLIGHT CYCLES, THIS INSPECTION WILL BE MONITORED UNDER LOG PAGE 2412695.