What was found
DURING M-CHECK, FOUND FLOOR SUPPORT CRACKED AT -Y794.3, FRAME 71-74 IN AFT GALLEY. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG NR 10N00344.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING M-CHECK, FOUND FLOOR SUPPORT CRACKED AT -Y794.3, FRAME 71-74 IN AFT GALLEY. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG NR 10N00344.