What was found
LONGERON 30 IN BS 908-960 HAS SEVERAL AREAS OF CORROSION. BLENDED CORROSION FROM BS 908-960, L30 IN AFT CARGO IAW SRM 53-00-05, REPAIR 3. THICKNESS CHECK PERFORMED IAW NTSPM 04-00-07, ORIGINAL THICKNESS .125, .093 LEG, REMAINING THICKNESS ON LEG AT BS 954 IS .061 BS 908-953 OF STR FOUND WITHIN LIMITS. BS 954-960 FOUND OUT OF LIMITS IAW SRM 53-00-05, REPAIR 3. A "U" CHANNEL WAS FABRICATED AND INSTALLED TO THE OUT OF LIMITS AREA IAW SRM 53-00-05 AND 51-03-07.