What was found
LEFT AILERON L/E HAS FRAYED COMPOSITE, APPROXIMATELY 13.5" FROM INBD EDGE. LEFT REMOVED DAMAGED AREA, 1.5" IAW SRM 57-60-01, REPAIR 1 AND SRM 51-70-04, PAR 4.C. FABRICATED REPAIR PLIES USING BMS 8-256TY4CL2 IAW SRM 51-70-04, PAR 4E. HOT BONDED REPAIR IAW SRM 57-60-01 AND SRM 51-70-04, PAR 4G. TAP TESTED REPAIR AREA, NO DEFECTS NOTED IAW SRM 51-10-06E.