What was found
CORROSION ON RT CUSP WEB X=-57 TO 61 FROM BS 916 TO BS 930 AT FLOOR STRUCTURE. CUSP WEB WAS REPAIRED IAW SRM 51-41-02, 53-00-55, FIG 216, AND 51-10-04, PAR 21, 15 AND 37.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON RT CUSP WEB X=-57 TO 61 FROM BS 916 TO BS 930 AT FLOOR STRUCTURE. CUSP WEB WAS REPAIRED IAW SRM 51-41-02, 53-00-55, FIG 216, AND 51-10-04, PAR 21, 15 AND 37.