What was found
CORROSION ON FLOORBEAM 765 AT AFT GALLEY AREA FROM FRAME 66+5" TO FRAME 68. REPLACED FLOORBEAM 765 BETWEEN FRAME C-66 TO C-70 IAW SRM 51-72-11 AND DWG D534-72780.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM 765 AT AFT GALLEY AREA FROM FRAME 66+5" TO FRAME 68. REPLACED FLOORBEAM 765 BETWEEN FRAME C-66 TO C-70 IAW SRM 51-72-11 AND DWG D534-72780.