What was found
CORROSION ON COUNTERSINK AND SETTLEMENT AREA OF FUEL ACCESS PLATE 1478C. FOUND 5 HOLE OUT OF LIMITS, MAXIMUM HOLE MEASURED WITH .543" BUSHING WAS FABRICATED AND INSTALLED WITH OD .329" COUNTERSINK .509" IAW SRM 51-22-2A, PAR 6, CONDITION II.