CORROSION ON CENTER FITTING AT FWD GALLEY AREA ON STR 23L BETWEEN FRAME 16 TO FRAME 20. REPLACED CENTER FITTING LOCATED AT FWD GALLEY AREA ON STR 23L BETWEEN FRAME 16 TO FRAME 20 IAW SRM 51-72-11 AND D5311226.