What was found
BLEND OUT ON UPPER FUSELAGE SKIN BS 858 BETWEEN LONG 5-6R. AREA WAS REPAIRED IAW SRM 53-02-01, FIG 202, SHEET 3 AND 51-10-04, PAR 15, 21. HFEC WAS PERFORMED AND CRACKS WERE NOT FOUND. PERFORM GENERAL VISUAL INSPECTION INITIAL AND REPETITIVE EA 8,000 CYCLES IAW SRM 53-02-1, PAR 6, REP 1.